In general, HP expects that your installation of the PSP will be done through the graphical installer that comes with the CD/ISO. Monitoring RAID drive health using StorCLI and MegaCLI plus other useful commands This entry was posted by Stewart S. Currently I have following hardware in my home lab - two HPE Proliant DL380 Gen8 (E5-2600 v2 series CPU), SuperMicro SYS-2028R-C1R4+ (E5-2600 v3 series CPU) and HPE Proliant DL380 G7 (X5600 series CPU). 01: Recommended: cp040734. After downloading the VIB package and storing it in the Datastore Server, install the package using ESXi Shell environment with this command. I want to add some disks to my array (DL380 Gen8 - P420i smart array). How To Secure Erase ESXi Disks (HPE or Generic Hardware) Posted by fgrehl on November 12, 2018 Leave a comment (3) Go to comments Since a couple of versions, vSphere comes with an erase function in the GUI. 7版) ===== 【ソ フ ト 名】 WBEM プロバイダ (670. To get the latest version, update your Windows. Introduction. 5 ssacliのインストール. HPE Gen9 Plus Custom Image for ESXi 6. 10302608 requires esx-update << 6. Installing VMware vSphere in this configuration means that the enabling device drivers must be available in the VMware vSphere installation images. 7 to manage from outside the HP Proliant and then migrate to the HP server later on. Click Start>All Programs>HP System Tools>HP Smart Storage Administrator Diagnostics Utility>Read Me; Open a command prompt. apt-get install ssacli Installation unter Ubuntu 18. sh This module uses ssacli, which can only be executed by root. x? " Petrovich September 8, 2017. نام شرکت hp همواره به عنوان یکی از شرکت های بزرگ تولید کننده سرور و تجهزیات ذخیره سازی در دنیا مطرح بوده و به تبع اون در کشور ما نیز بخش اعظمی از زیرساخت سروری و ذخیره سازی سازمان ها شرکت ها و حتی دیتا سنترها را محصولات. v00 file, which as it turns out is located at the root of the ESXi 6. “ssacli controller slot=0 modify hbamode=on” It was executed successfully and the servers say hardware RAID is disabled on boot. Read about different Proliant models and other competitors such as: Dell, IBM or Supermicro. 7U1 Install CD: Notes: VMware vSAN environment is not supported with the HPE ProLiant Gen10 Smart Array Controller smartpqi driver version 1. /check_cciss -v # ----- # RAID OK: Smart Array 6i in Slot 0 array A logicaldrive 1 (67. edu), of the University of Wisconsin Space Science and Engineering Center. Following errors. It also covers advanced installation methods such as kickstart installations, PXE installations, and installations over VNC. Ssaducli Smart Storage Administrator Diagnostic Utility (SSADU) CLI. If there is an older version of ACU CLI installed on the system, you must use rpm -e hpacucli to remove it first. 5 upgrade failed with no space left on device → Having issues with pfsense booting or crashing on ESX 6. Get sascli for HPSA Smart Array with sascli on Ubuntu. Otherwise you have to reboot and wait 10 minutes (no joke) to enter the 'Smart Array Configuration Utility' to make changes to the storage configuration. # ssacli controller slot=0 physicaldrive 1I:1:2 show Smart Array P440ar in Slot 0 (Embedded) array A physicaldrive 1I:1:2 Port: 1I Box: 1 Bay: 2 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 300 GB Drive exposed to OS: False Native Block Size: 512 Rotational Speed: 15000 Firmware Revision: HPD2 Serial Number: 0TG8T4GP Model: HP. hpacucli which was later renamed to hpssacli which is now known as ssacli is a tool to access the HP RAID controllers from within the operating system. 7-bundle-11. While you could still install it (as I did from an internal repository) it won't work anymore on Gen9 blades. Thanks for contributing an answer to Unix & Linux Stack Exchange! Please be sure to answer the question. Eine funktionierendes How-To für die Installation von den VMWare Tools in einem Ubuntu Server Gast gibt es hier auf dem Ubuntublog. If this is unable to pull the serial number then I would double check your BIOS settings and make sure that you have S. Navigate to the HP Web Portal for Support and Driver Download. This install method works on latest LTS ubuntu Release, Ubuntu 14. HP Smart Storage Admin CLI (ssacli) installation and usage on Proxmox PVE (6. Cette procédure couvrira juste l’installation de tous les composants de la suite logicielle. Install and configure a local firewall. Currently I have following hardware in my home lab – two HPE Proliant DL380 Gen8 (E5-2600 v2 series CPU), SuperMicro SYS-2028R-C1R4+ (E5-2600 v3 series CPU) and HPE Proliant DL380 G7 (X5600 series CPU). /ssacli controller slot=0 modify hbamode=on forced After rebooting the machine, it displays the following message during the controller init:. ProLiant Gen10: Tour of a DL380 Gen10 Server - Duration: 13:07. In order to use the online. Select the primary network interface, if prompted: Assign IP address, subnet mask, and default gateway. As is, it will install the command line utilities to configure ILO and your RAID controllers. This will copy cciss source files to /var/hp/storage/cciss directory and build cciss module binary against installed kernel. Would you mind updating the package? Thanks for all your hard work. exe), but in my case it works more slowly than HP Smart Array Configuration. Si tu es sous XP tu cliques-droit sur Poste de Travail et tu choisis "Gérer les disques". HP SSACLI 工具使用-windows2008 阵列卡型号--win2008 R2 HP DL388 G9 P440ar1. At the moment there is no specific version for Debian buster, but the stretch package should work just fine. That's was so simply, i just didn't do the last step - vmkfstools --growfs. Excellent thank you. 7 Justin Braun; January 6, At this point, the installer will start the scan devices and look for places that it can install ESXi or where it might already be installed. In the case of hardware RAID, multiple hard disk drives are combined to one logical drive and data is distributed across multiple hard drives. Run the command “esxcli software vib install –d /FQN/xxx. list and insert the following lines into that fil. Storage management - ssacli tool. In this series we will see on how you can easily get information using commands in ESXi & how you can manage the ESXi using command line. Increase Size. From the debian-boot mailing list: * pkgsel: - Ensure tasksel is installed, regardless of its priority. VSAN will not display the physical drive bay number of the drive however you may use ssacli tool that is a part of HPE custom ESXi image. 5 (Driver Component). Or, if you don't want to get to the hpacucli/hpssacli prompt, you can just enter the following directly in the Linux prompt:. 9 installation program (anaconda) and to install Red Hat Enterprise Linux 6. 如: # hpssacli ctrl all show config (可查看硬盘状态). Note that only the English language selection is currently supported. Often referred to as the Ops Console, you can use this console to view data about your cloud infrastructure in a web-based graphical user interface (GUI) to make sure your cloud is operating correctly. debian-installer. SSAC Hockey – South Side Athletic Club. For install this script you need to do some steps: Install HP Smart Array Configuration Utility. I downloaded ssacli-2. This is the third part where we will see some of the basic commands on how you can administer & manage the esxi server using the esxcli. Full text of "Amiga World Magazine (July 1992)" See other formats. - Terrance Jan 15 '19 at 0:22. ssacli ctrl slot=0 lk all show ssacli ctrl slot=0 add lk=3MXBB-P2ZCC-ML82H-PB8CS-ZXXXX HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) licensekey 3MXBB-P2ZCC-ML82H-PB8CS-ZLZNR (OK) Attivare rc. You will get many results out of which select the "HP Prolaint DL380 G7 Server" 4. /ssacli ctrl slot=5 lk XXXXXXXXXXXXXXXXXXXXXXXXX delete Related sources A couple of interesting links related to the HPE Storage Controller tool for VMware ESXi:. 04 trusty and Ubuntu 16. deb file) and issue following command prompt>dpkg -i hpcciss-src-x_x_xx. It also covers advanced installation methods such as kickstart installations, PXE installations, and installations over VNC. Fur this purpose, the HPSSACLI utility will be used, which is part of HP ESX i Utilities Offline bundles, but also part of customised HP ESX i images for ProLiant servers. , create a file e. To be able to install it with apt etc. etc etc hp_p421i. I have an HP Proliant N40L MicroServer with an HP Smart Array P410 raid card. If your Smart Array controller designation begins with the letter P, such as the P420i: sudo ssacli controller slot=0 modify hbamode=on. Similar to installing the Avago/LSI SMIS provider, the process to install the StorCLI is straightforward and simply includes copying the. 8 GB, RAID 1+0, OK) # [Controller Status: OK Cache Status: OK Battery Status: OK] # # RAID CRITICAL - HP Smart Array Failed: Smart Array 6i in Slot 0 (Embedded) \ # array A logicaldrive 1 (33. HPE Custom Image for ESXi 6. zip” on the ESXi host where FQN is the fully qualified path to each hot fix file. Rebooted the server and now it runs Storage Manager. 7uX-mgmt-bundle-3. 어레인 콘트롤러 확인 - 0b => ctrl all show Dynamic Smart Array B140i in Slot 0b 2. Using the Command Line Interface (CLI) Overview Overview The CLI is a text-based command interf ace for configuring and monitoring the switch. It also covers advanced installation methods such as kickstart installations, PXE installations, and installations over VNC. Standard VMware ESXi ISO, is the easiest and most reliable way to install ESXi on HPE servers. 20181203: * leftovers from revert of PR 586 (bsc#1108867) Update to version 8. The HPE Smart Storage Administrator CLI (HPE SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. # Show controller slots ssacli ctrl all show config # Disable HBA Mode ssacli controller slot=0 modify hbamode=off # Recheck controller status ssacli controller slot=0 show Posted in Hardware , Kernel , Linux , Scriptíky , virtualizace by: admin No Comments. So I will provide step-by-step instructions instead for how to do the required modifications on your own using a Windows machine. Verified if I have RAID and the server model [email protected]:~ # lspci | grep -i raid 02:00. HP Smart Storage Administrator User Guide Abstract This document identifies, and provides instructions for, the tools available for configuration, management, monitoring, and d iagnosing of HP ProLiant controller and server products. 0) 【登 録 名 】 smx-provider-600. my software hp ssacli some exec file setup to /opt/xxxxxx it's not doing symlink automatic. HP Smart array CLI commands (these should apply to any system with the CLI installed) Show configuration /opt/hp/hpssacli/bin/hpssacli ctrl all show config. Now edit the check_smartarray. Oregon State University. 注意,主机 B 中必须安装有 ssacli 工具. notes and documents. exe (in my case it is C:Program Fileshphpssacli inhpssacli. In the past I managed it through the Array Configuration Utility by rebboting the host. I downloaded ssacli-2. installing the hpucacli or ssacli utilies. You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long. Installation and Usage Instructions Installing HP ACU-CLI: HP ACU-CLI is distributed using Red Hat Package Manager (RPM) packages. You’ll get a blue wave splash screen for a bit and then the GUI Array Configuration Manager. exe) and the HP Smart Storage Administrator CLI (cp019296. Rebooted the server and now it runs Storage Manager. Use the HP Smart Storage Utilities for Linux to modify the RAID configuration within the host OS; Option 2 sounded much better. VMware vSphere ESXi Storage Center systems with Front End SAS connectivity show lun capacity 0MB Date Published: 2/5/2019 VMware Horizon Installation of Horizon View Agent 7. VMware vSAN environment is not currently supported with the HPE ProLiant Gen9 Smart Array Controller nhpsa driver version 2. Management Component Pack (MCP) phiên bản cũ tên là HP Proliant Support Pack (PSP), là một gói bao gồm các chương trình giúp cho bạn quản lý, điều khiển và giám sát các thành phần phần cứng của máy chủ HP. 4 ssacliのインストール # apt-get install ssacli 3. I have an HP Proliant N40L MicroServer with an HP Smart Array P410 raid card. From Pike release ilo hardware type supports ProLiant Gen10 systems which have iLO 5 management engine. 어레인 콘트롤러 확인 - 0b => ctrl all show Dynamic Smart Array B140i in Slot 0b 2. rpm which has the support for HPE P/E-Class SR Gen10 controllers. which returns: Smart Array P410 in Slot 1 (sn: PACCRID111003N3) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (1. Hi, I rarely use esxi shell, so I'm sure it's a noob question, sorry :). HPE ProLiant Smart Array Controller Driver for VMware vSphere 6. Installing VMware vSphere in this configuration means that the enabling device drivers must be available in the VMware vSphere installation images. If I currently want to use my headphone mic, I have to uninstall the Realtek driver, reboot the PC, then press 'reboot later' so that I can work for a while with my laptop detecting my mic. 3 About Lazy Counters 5. What we don’t know is the status of the Parity Initialization Progress display, which is still at 0%. cmd to run startup scripts when Windows PE (WinPE) first runs. First I needed to get a copy of the xorg. 5uX-mgmt-bundle-3. 5 The XFS File System 5. db1139: Rack location: Anywhere on row B - receive in system on procurement task T214066 - rack system with proposed racking plan (see above) & update netbox (include all system info plus location) - bios/drac/serial setup/testing - RAID10 stripsize 256kb. This blog post shows you how to generate an Array Diagnostic Utility (ADU) report on an Hewlett Packard Enterprise (HPE) server that is running VMware® ESXi™ version 5. exe (in my case it is C:Program Fileshphpssacli inhpssacli. Installing a new drive and preparing it for use in the system can be accomplished in one of two ways: Insert the drive and reboot the host into the Smart Storage Utility where you can configure the drive. 5 U1 Install CD | 700 MB. The name of the application is HP Array Configuration Utility CLI and. The diagnostic features in HP SSA are also available in the standalone software HP Smart Storage Administrator Diagnostics Utility CLI (on page 101). supplied with the controller, and then install the Smart Component onto the server. Monitors controller, cache module, logical and physical drive state and temperature using ssacli tool. This disables transactions and creates the rendevous file install-db, for utilities to perform diagnostic and initialization operations. HPE Serviceguard for Linux (SGLX) is a High Availability (HA) and Disaster Recovery (DR) clustering solution that increases up-time for your critical applications by protecting them from a multitude of infrastructure and application faults across physical or virtual environments over any distance. While playing with multiple vSAN disks you may came into a a problem how identify a disk with software errors based on ESXi NAA ID. Fatal error: 6 (Buffer too small) when loading /ESXi60/sb. 4 ssacliのインストール # apt-get install ssacli 3. How to generate HP Array Diagnostic Report (ADU Report) in Linux We need to understand what is an Array, RAID and Array Configuration Utility (ACU). Use Wpeinit and Startnet. I have a HP Proliant server that is using hardware RAID for the boot disk but when I used hpacucli no status was shown [email protected]:~ # hpacucli ctrl all show config Error: No controllers detected. All I had to do was boot from the HP customized ESXi installer media, switch to the console (alt+F1), login as root with no password, cd to the /opt/hp/ssacli/bin directory and run the following commands:. Accessing the RAID setup on an HP Proliant DL380 G7 When the HP Proliant DL380 G7 boots up the only displayed BIOS options are F9 for Setup, F11 for the boot disk menu, but neither other these take you to the RAID setup. That's was so simply, i just didn't do the last step - vmkfstools --growfs. It can be downloaded from HP web site for free. Select the primary network interface, if prompted: Assign IP address, subnet mask, and default gateway. You just have to edit. However, we found that the performance is very poor after disable the write cache and we tried the database import using one node andd the other node disabled. 5501331820--Avago--VMwareCertified--2020-02-17. Eine funktionierendes How-To für die Installation von den VMWare Tools in einem Ubuntu Server Gast gibt es hier auf dem Ubuntublog. Set a static IP in VeeamPN appliance. Open Powershell as Administrator and with Domain Admin Writes and run. HP assumes. Select the location. hello together, i am looking for a way to monitor the raid controllers / arrays and the single disks of HPE Servers. If it is not installed, you can use the steps provided in this blog to install it. I want to add some disks to my array (DL380 Gen8 - P420i smart array). list and insert the following lines into that fil. It also covers advanced installation methods such as kickstart installations, PXE installations, and installations over VNC. As is, it will install the command line utilities to configure ILO and your RAID controllers. You can look up the other package names available for your distribution by examining the Packages file as in this example here:. Most of the information you can get via the GUI, but sometimes it's just faster to fire up Putty (or PuttyTray …) and launch one or two commands to get the info. Perhaps I'm overlooking something, but I would like to pass my p420i through from ESXi into a VM for ZFS. Two ways to execute the command. I've come across various documentation online of people running the command "controller. With HPE SSA, you can also configure. The information presented here is intended for educational use by qualified computer technologists. Buy HP ISS 652564-B21 300GB 6G SAS 10K RPM SFF Gen8 Hardrive: Internal Hard Drives - Amazon. Enter install (all lower-case, exactly as spelled out here) to start installation. exe is installed. 7uX-mgmt-bundle-3. 5 U3 Install CD Contains: lsi-mr3--7. Following errors. vib file use the -v option. If it is already installed, execute [Uninstallation Procedure] step 3,4 and then re-execute from step 10. rp m (13 MB) and installed. I have updated my home lab to vSphere 7 for exception of one host. Archived User and Install Guides Microsemi Adaptec RAID Controller - Installation And User's Guide 1/2019 (PDF 3MB) Event Monitor v3. Mentioned in SAL (#wikimedia-operations) [2019-04-12T07:12:24Z] Manually install ssacli on db2[097|098|099|100|101|102] T220787 T220572 MoritzMuehlenhoff added a comment. This update for documentation-suse-openstack-cloud fixes the following issues: Update to version 8. In my case, it sees the 2 TB hard disk I have installed. Network interfaces depend highly on your actual setup. 29, but the requirement cannot be satisfied within the ImageProfile. zip file, use the -d option. Introduction to the command line tools. Rebooted the server and now it runs Storage Manager. $ sudo rpm -qip GeoIP-1. To display the RAID status, enter: ssacli ctrl all show config. 20181128: * Adding back removed space * Updating Fernet. When attempting to load a vib onto an ESXi 6. zip ssacli-3. Sinon soit effectivement tu peux booter depuis un Cd d'install, ou alors si tu possèdes une disquette de démarrage W98, tu bootes dessus et ensuite tu tapes fdisk. 4 running good I using HARD RAID5 (Smart Array P440ar) ; no problem for the storage I add new Array on my RAID #ssacli ctrl all show config Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH8Z3EY) Port Name: 1I Port Name: 2I. , create a file e. Otherwise you have to reboot and wait 10 minutes (no joke) to enter the 'Smart Array Configuration Utility' to make changes to the storage configuration. HPE Smart Storage Administrator (HPE SSA) offers a single interface that quickly sets up, configures and manages the servers /smart-array-controllers-and-smart-host-bus-adapters. That's was so simply, i just didn't do the last step - vmkfstools --growfs. [email protected]:~ # yum install hpacucli-9. Install and configure Azure PowerShell Command line az group create --name --location #use this command when you need to create a new resource group for your deployment. Die optimale Steuerung und Konfiguration von ESX und ESXi Virtual Machines gelingt durch Direktbefehle. v00 file, which as it turns out is located at the root of the ESXi 6. 5 on HPE Proliant DL560 Gen8 Server Integrated Lights-Out, or iLO, is a proprietary embedded server management … How to Open HPE iLO Remote Console to Manage Servers Remotely. list Then add the source at the end of the file For Ubuntu 14. 28, but the. HPE Management Component Pack or HPE MCP provides agent software for use on community-supported distributions. دستورات CLI برای مدیریت HPE Smart Array در ESXi • بلاگ رسانگار %. See Getting Started with vSphere Command-Line Interfaces. Conflicting VIBs while upgrading ESXi 5. You don't need to use USB drive for bootloading into xpenology under esxi. [ [email protected] ~]# rpm -qa |grep hpacu hpacucli-9. For VMware ESXi 5. Grandfather Eligibility & Boundary Map. Buy HP ISS 652564-B21 300GB 6G SAS 10K RPM SFF Gen8 Hardrive: Internal Hard Drives - Amazon. Introduction to the command line tools. In Windows the CLI tool is located at C:\Program Files\Smart Storage Administrator\ssacli\bin\ Add a Physical Drive to a Logical Drive. If it is not installed, you can use the steps provided in this blog to install it. hpasmcli stands for HP Server Management Application and Agents Command Line Interface It comes with HP ProLiant Support Pack (PSP) and can be installed in HP ProLiant Servers to view, modify the BIOS / System settings such as hyper-threading, boot sequence control, and UID LEDs, etc. To install the HP ACU-CLI application, enter: rpm -i 3. 11/26/2019; 5 minutes to read +3; In this article. # ssacli controller slot=0 modify hbamode=on forced. If passthrough is not supported then put each individual disk in its own RAID0 disk group. This disables transactions and creates the rendevous file install-db, for utilities to perform diagnostic and initialization operations. sh from https: Now install the tool: sudo apt update && sudo apt install ssacli. If it is already installed, execute [Uninstallation Procedure] step 3,4 and then re-execute from step 10. something like that. In the past I managed it through the Array Configuration Utility by rebboting the host. Bạn có thể sử dụng cổng console iLO chức năng Virtual Media iLO nhằm mount file ISO để cài đặt một hệ điều hành hoặc một chương trình mà không cần trực tiếp. For troubleshooting, run esxcli commands in the ESXi Shell. 9 installation program (anaconda) and to install Red Hat Enterprise Linux 6. The CLI gives you access to the switch’s full set of commands while providing the same password protection that is used in the web browser interface and the menu interface. Introduction to Linux - A Hands on Guide This guide was created as an overview of the Linux Operating System, geared toward new users as an exploration tour and getting started guide, with exercises at the end of each chapter. HPE Management Component Pack or HPE MCP provides agent software for use on community-supported distributions. 4240417–HPE. Install vCLI or deploy the vSphere Management Assistant (vMA) virtual machine. Ask Question Asked 3 years, 8 months ago. Similar to installing the Avago/LSI SMIS provider, the process to install the StorCLI is straightforward and simply includes copying the. Fur this purpose, the HPSSACLI utility will be used, which is part of HP ESX i Utilities Offline bundles, but also part of customised HP ESX i images for ProLiant servers. /ssacli ctrl slot=1 licensekey XXXXX-XXXXX-XXXXX-XXXXX-XXXXX # License key removal. HP Smart Array Advanced Pack 1. nano /etc/apt/sources. list deb http 2. Also you may use to HP Smart Storage Administrator (ssacli. 04 (Bionic): Führen Sie zum hinzufügen des Repository von HP folgenden Befehl auf Ihrer Kommandozeile Ihres Servers aus:. Excellent thank you. To configure the P420i RAID controller, It's highly recommended to install the ssacli tool from HP. 第二步: 在主机 A 中安装 HPE ADU CLI 工具. Select your ESXi version for Operating System. 2 thoughts on " How to expand VMFS datastore from the command line (CLI) on vSphere 5. The boot drive is an SSD running Ubuntu Server 14. [Linux] CentOS 7 HP SSACLI Command 사용법 [Linux] CentOS 7 HP SSACLI Command 사용법 벤더(IBM,HP,Dell 등) 의 x86 하드웨어에서는 Linux 운영체제 상에서 하드웨어 레이드 컨트롤러의 상태를 확인 할 수 있는 도구들을 제공하고 있습니다. Mentioned in SAL (#wikimedia-operations) [2019-04-12T07:12:24Z] Manually install ssacli on db2[097|098|099|100|101|102] T220787 T220572 MoritzMuehlenhoff added a comment. cmd to run startup scripts when Windows PE (WinPE) first runs. There's a vib for it but it was already installed in my HP server ESXi shell. Download the add_repo. The hpssacli package has been superceded by the ssacli package. 7 to manage from outside the HP Proliant and then migrate to the HP server later on. View logical volume config (detailed). hockey For SSAC resident players that now reside in a new boundary, there is a one-time grandfather option to declare to remain at SSAC for those eligible. x) Why use HP Smart Storage Admin CLI? You can use ssacli (smart storage administrator command line interface) tool to manage any of supported HP Smart Array Controllers in your Proxmox host without need to reboot your server to access Smart Storage Administrator in BIOS. If you are…. The information presented here is provided free of charge, as-is, with no warranty of any kind. Would you mind updating the package? Thanks for all your hard work. Installing VMware vSphere in this configuration means that the enabling device drivers must be available in the VMware vSphere installation images. rpm Use the command hpssacli to check the disks in the disk array [email protected]:~ # hpssacli ctrl all show config. You’ll get a blue wave splash screen for a bit and then the GUI Array Configuration Manager. I installed Ubuntu Server 14. If you are lucky and get a “Could not find a trusted signer” when trying to install the vib the workaround is to add “–no-sig-check” at the end of the esxcli command, after the file path. 01: Recommended: cp040734. hpacucli which was later renamed to hpssacli which is now known as ssacli is a tool to access the HP RAID controllers from within the operating system. vib file use the -v option. Perhaps I'm overlooking something, but I would like to pass my p420i through from ESXi into a VM for ZFS. This update for documentation-suse-openstack-cloud fixes the following issues: Update to version 8. rp m (13 MB) and installed. 1las, 12 a ]a 18. /ssacli ctrl slot=0 ld2 modify size=max forced. Run the command “esxcli software vib install –d /FQN/xxx. # apt-get install alien # alien --scripts hpssacli-2. So if you need the data in SSDs please backup all of those. You can help protect yourself from scammers by verifying that the contact is a Microsoft Agent or Microsoft Employee and that the phone number is an official Microsoft global customer service number. Installation and Usage Instructions Installing HP ACU-CLI: HP ACU-CLI is distributed using Red Hat Package Manager (RPM) packages. Exemple concret d'utilisation de la hpssacli qui permet de manipuler l'ensemble des éléments d'une carte RAID contrôleur HP dans l'OS (sans reboot donc). Preparing for Cisco NFVI Installation. HP Smart Array P420 RAID controller RAID configuration via KVM on a DELL server (iDRAC) H310 / H710 / H730 RAID configuration via KVM on a DELL server (iDRAC) H200. 22404 - User's Guide (PDF 169KB). I can see all the disks under Storage –> Devices. Lets Build Updated Kali Linux ISO, all Packages Updated Are you tired of downloading Kali Packages every-time you re-install? Kali Linux 2016. ssacli: ssacli is the controller utility for HP based controller. This will copy cciss source files to /var/hp/storage/cciss directory and build cciss module binary against installed kernel. Bạn có thể sử dụng cổng console iLO chức năng Virtual Media iLO nhằm mount file ISO để cài đặt một hệ điều hành hoặc một chương trình mà không cần trực tiếp. esxcli software vib install -v ssacli-3. August 14, 2014. I’ve tried to install the esxi6. While you could still install it (as I did from an internal repository) it won't work anymore on Gen9 blades. To configure the P420i RAID controller, It's highly recommended to install the ssacli tool from HP. It should show how many physical drives are detected. The ESXi hidden / unsupported console is a “Linux-like” interface but extremely light when compared to a real Linux installation. Install rpm files of filename in procedure 2. The installation guide of RAC said that we have to disable "Write Cache" in Device Manager->Disk->Policy->Uncheck "Enable Write Cache on disk". Smart Storage Administrator (SSA) Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array Controllers # apt-get install ssa. 5 installation [[email protected]:~] esxcli software install I get the error: Error: Unknown command or namespace software install Has anybody seen this. If no exclamation point appears next to the name of the device and the device does not function correctly, manually uninstall and reinstall the device drivers. Severity Recommended. vib files to ESXi’s /tmp directory and install them. exe), but in my case it works more slowly than HP Smart Array Configuration. You will get many results out of which select the "HP Prolaint DL380 G7 Server" 4. 7U1 Install CD: Notes: VMware vSAN environment is not supported with the HPE ProLiant Gen10 Smart Array Controller smartpqi driver version 1. I gave the HBA a kick with `ssacli ctrl all rescan` after that for good measure, I'm not sure I actually needed to. The vSphere Command-Line Interface Reference lists help information for all ESXCLI commands. 7 to manage from outside the HP Proliant and then migrate to the HP server later on. A device driver is not installed or a hardware device does not function correctly after you install a Windows Vista Service Pack. Most of the information you can get via the GUI, but sometimes it's just faster to fire up Putty (or PuttyTray …) and launch one or two commands to get the info. HPE Custom Image for ESXi 6. # rpm -ivh ssacli-x. دستورات CLI برای مدیریت HPE Smart Array در ESXi • بلاگ رسانگار %. You can collect ADU report in many ways but this is very short, reliable and perfect method to collect this report. HP SSACLI 工具使用-windows2008 阵列卡型号--win2008 R2 HP DL388 G9 P440ar1. HP Smart Array P420 RAID controller RAID configuration via KVM on a DELL server (iDRAC) H310 / H710 / H730 RAID configuration via KVM on a DELL server (iDRAC) H200. Create a 2 cylinder raw partition on a disk. $ sudo ssacli ctrl all show Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH992F5) Smart Array P441 in Slot 2 (sn: PDNMH0ARH84030). ===== WBEM プロバイダ およびCLIツール (VMware ESXi 6. Just a head's up, the RAID management utility has been renamed from hpacucli to hpssacli on newer Proliant servers. I had problems with the esxi web GUI - I wasn´t able to configure a network to my vm´s … And I´ve got many display problems and it was extremly slow so I decided to install the 6. /ssacli ctrl slot=5 lk XXXXXXXXXXXXXXXXXXXXXXXXX delete Related sources A couple of interesting links related to the HPE Storage Controller tool for VMware ESXi:. Install rpm files of filename in procedure 2. 9 on 32-bit and 64-bit x86 systems, 64-bit Power Systems servers, and IBM System z. i think when initrd load install filesystem, some script or conf file write command like ln -s /usr /mnt/runtime/usr. Buy HP ISS 652564-B21 300GB 6G SAS 10K RPM SFF Gen8 Hardrive: Internal Hard Drives - Amazon. 将该文件拷贝到 VMware 系统下,并登录 VMware ESXi 的命令行下执行 # esxcli software vib install /root/ssacli-3. Hi, I rarely use esxi shell, so I'm sure it's a noob question, sorry :). 1 About the XFS File System 5. Here's a quick and dirty, no-frills bash script to install the HP Server Management Tools on Ubuntu Server. sas cli https://wiki. o GUI, CLI - See “Launching SSA” o Scripting - Run the ssascripting. 0+ installed (I installed 4. This is an easy and quick way for building updated Kali Linux ISO for Kali 2016. Install Solaris 2. Linux Notes: Managing HPE RAID hardware. SAN configuration One common implementation for VMware vSphere is a boot-from-SAN configuration. If it is missing you easily download it from the HP web site:. Accessing the RAID setup on an HP Proliant DL380 G7 When the HP Proliant DL380 G7 boots up the only displayed BIOS options are F9 for Setup, F11 for the boot disk menu, but neither other these take you to the RAID setup. 전체보기(127); 생일용품[케이크토퍼](1) oracle(16); 리눅스 기초 ; 성능(cpu,mem,disk)(1) samba(1); 보안(1); 튜닝(1); grub. This install method works on latest LTS ubuntu Release, Ubuntu 14. 4 ssacliのインストール # apt-get install ssacli 3. 0 As most of us would be aware, whenever we call to HP support regarding drive, array controller battery etc related issues, the first this they ask for is Array Diagnostic Utility aka ADU report. It includes all of the required drivers and management software to run ESXi on HPE servers, and works seamlessly with Intelligent Provisioning. x plus patches. The -E CT_ID command line switch can be used to show only the processes running inside the Container with the ID specified. 5-bundle-2. Two ways to execute the command. Either use the HPE-Customized bundle or install it from the HPE Vibs Depot. It should show how many physical drives are detected. 2 thoughts on " How to expand VMFS datastore from the command line (CLI) on vSphere 5. rpm packages Install Netdata with kickstart. With HPE SSA, you can also configure. Install vCLI or deploy the vSphere Management Assistant (vMA) virtual machine. I have a HP Proliant server that is using hardware RAID for the boot disk but when I used hpacucli no status was shown [email protected]:~ # hpacucli ctrl all show config Error: No controllers detected. Hpssacli rebuild status. x? ” Petrovich September 8, 2017. This is a description on how to check the status of a HP Smart array and report disk failures by email from the ESX i host using HP command line utilities. RHEL 5,6 & 7: yum groupinstall group-pkg-name RHEL 2,3,4 : up2date "@group-pkg-name". You should be all set. During an installation or upgrade, the installer checks the compatibility of the host CPU with vSphere 7. Linux Notes: Managing HPE RAID hardware. The information presented here is intended for educational use by qualified computer technologists. Peut ont gérer sur edomus plusieurs ouverture en % exemple ouvrir la porte du garage a 20 ou 70 % au choix?. sh from https: Now install the tool: sudo apt update && sudo apt install ssacli. deb包) # dpkg -i hpssacli-2. Type “exit” to close the console. Install Azure CLI with yum. (11) Execute the following command and confirm the installation of smx-provider, ssacli which are VIB packages. I just followed these instructions to install this tool on. something like that. It uses sudo and assumes that it is configured such that the netdata user can execute ssacli as root without password. The Build Plan ProLiant HW - Smart Array Set RAID 1 uses the SSACLI scripting toolkit with the configuration file Smart Array Configuration - Set RAID 1 as input. Choose the Operating System. rpm packages Install Netdata with kickstart. 7 Update 1 build I've got the following error: [DependencyError] VIB VMware_bootbank_esx-base_6. I'd like to present the individual disks to the OS, which requires placing the SSA into HBAMode. For example, some of the most basic Linux commands work like ls (to list files), cd (to change directories), rm (to remove files), cp (to copy files), vi (to edit files), and reboot. nano /etc/apt/sources. In normal cases, it pops out when Microsoft decides that certain apps you are to open. 查看控制器状态=>ctrl all show status2. Bạn có thể sử dụng cổng console iLO chức năng Virtual Media iLO nhằm mount file ISO để cài đặt một hệ điều hành hoặc một chương trình mà không cần trực tiếp. Ask Question Asked 3 years ago. I've come across various documentation online of people running the command "controller. Newly built cciss driver will be placed under /var/hp/storage/cciss, if build is successful. I just followed these instructions to install this tool on. something like that. In my case, it sees the 2 TB hard disk I have installed. Chapter Title. Lets Build Updated Kali Linux ISO, all Packages Updated Are you tired of downloading Kali Packages every-time you re-install? Kali Linux 2016. ===== WBEM プロバイダ およびCLIツール (VMware ESXi 6. 7 Justin Braun; January 6, At this point, the installer will start the scan devices and look for places that it can install ESXi or where it might already be installed. zip 【著 作 権 者】 Hewlett Packard Enterprise 【対 象 機 種】 [本体装置] - Express5800/R120h-1M. Activities. 5 on HPE Proliant DL560 Gen8 Server Integrated Lights-Out, or iLO, is a proprietary embedded server management … How to Open HPE iLO Remote Console to Manage Servers Remotely. 11 [리눅스] HP Smart Array CLI commands (0) 2015. Linuxの技術情報のSmart Storage Administrator-CLI(SSA Command Line Interface: ssacli)- オンライン版のページです。Linux上で SmartArrayコントローラの設定、アレイ・論理ドライブの作成、論理ドライブのオンライン拡張、コントローラ・ディスクの診断等をコマンドラインで行える様にするためのユーティリティ. 0+ installed (I installed 4. hotplugging while using the onboard p420i. DIB_SSACLI_URL should contain the HTTP(S) URL for downloading the RPM package for ssacli utility. Viewed 3k times 1. 查看控制器状态=>ctrl all show status2. After setting the RAID all of the data in SSD will lost. 5-bundle-2. 1 Product Note (802-5314-10) or SPARCstorage Array Software and Volume Manager 2. 7-bundle-11. The information presented here is intended for educational use by qualified computer technologists. centos 5. 2) Smart Storage Administrator CLI for VMware ESXi (3. Click Start>All Programs>HP System Tools>HP Smart Storage Administrator Diagnostics Utility>Read Me; Open a command prompt. HPE Smart Storage Administrator Diagnostic Utility CLI reports. i think when initrd load install filesystem, some script or conf file write command like ln -s /usr /mnt/runtime/usr. For RHEL distrib for remote installation and repositories installation to yum OK, Here we have some additional details : RHEL 2,3 and 4 : up2date -i pkg-name RHEL5,6 : yum install pkg-name RHEL7 yum group install group-pkg-name. 5-util-bundle-3. 14 [리눅스] git 설치(gitlab) (0) 2015. 22404 - User's Guide (PDF 169KB). com FREE DELIVERY possible on eligible purchases. To configure the P420i RAID controller, It's highly recommended to install the ssacli tool from HP. Network interfaces depend highly on your actual setup. 7版) ===== 【ソ フ ト 名】 WBEM プロバイダ (670. Use Wpeinit and Startnet. This directory is commonly C:\Program Files\hp\hpssaducli\bin. I can also clear the partition table and add a Datastore on all disks. However, slight differences exist, requiring you to run HP SSA CLI through the VMware vSphere esxcli command-line utility. Currently I have following hardware in my home lab – two HPE Proliant DL380 Gen8 (E5-2600 v2 series CPU), SuperMicro SYS-2028R-C1R4+ (E5-2600 v3 series CPU) and HPE Proliant DL380 G7 (X5600 series CPU). From the debian-boot mailing list: * pkgsel: - Ensure tasksel is installed, regardless of its priority. zip but this over-written the smx-limited version with smx-provider-670. With the full version of VMware ESXi Server, that has been available for years, there is a special "virtual machine" that runs a modified version of Red Hat Linux Enterprise. In normal cases, it pops out when Microsoft decides that certain apps you are to open. Search for the controller model. You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long. 4 ssacliのインストール # apt-get install ssacli 3. Ingram Micro, HPE and the BTC / Solution Center. If you are lucky and get a “Could not find a trusted signer” when trying to install the vib the workaround is to add “–no-sig-check” at the end of the esxcli command, after the file path. I will keep you posted, thankx for all the fast help. 5 to ESXi 6. 0 RAID bus controller:…. I can see via ILO temperature / Fans / PSU etc. 7 installation. PS This gives us our ssacli-4. The name of HP has always been one of the largest manufacturers of servers and storage equipment in the world, and as a result, the largest part of organizations across world, a large part of the server infrastructure and storage organizations, companies and even data centers are HP products. What we don’t know is the status of the Parity Initialization Progress display, which is still at 0%. After installation, I created the new OMD monitoring site: omd create ssec This creates a new site that runs its own stack of Apache, Nagios, Check_MK and everything else in the OMD distribution. CrystalDiskInfo will display this information as well as all other S. Here we create our own yum repository on a fresh up-to-date installation of Centos 7. This task will track the racking, setup, and installation of the 2 dedicated dump slaves. js, that will utilize a remote backend as source. Install NodeJS, if you don't have it yet. SSAC Hockey – South Side Athletic Club. 14 [리눅스] git 설치(gitlab) (0) 2015. The CLI gives you access to the switch's full set of commands while providing the same password protection that is used in the web browser interface and the menu interface. list in /etc/apt/sources. hpasmcli stands for HP Server Management Application and Agents Command Line Interface It comes with HP ProLiant Support Pack (PSP) and can be installed in HP ProLiant Servers to view, modify the BIOS / System settings such as hyper-threading, boot sequence control, and UID LEDs, etc. HP Smart Array P420 RAID controller RAID configuration via KVM on a DELL server (iDRAC) H310 / H710 / H730 RAID configuration via KVM on a DELL server (iDRAC) H200. 0 GA Install CD 2012-03-23 Updated for Hitachi Custom Image for ESXi 5. Sinon soit effectivement tu peux booter depuis un Cd d'install, ou alors si tu possèdes une disquette de démarrage W98, tu bootes dessus et ensuite tu tapes fdisk. During an installation or upgrade, the installer checks the compatibility of the host CPU with vSphere 7. You can help protect yourself from scammers by verifying that the contact is a Microsoft Agent or Microsoft Employee and that the phone number is an official Microsoft global customer service number. 04, I'm running the HWE kernel but everything was working properly with the standard kernel a couple of days ago w. So here is the step by step guide how to setup "RAID 0" with two SSDs. If you are…. The information presented here is intended for educational use by qualified computer technologists. ===== WBEM プロバイダ およびCLIツール (VMware ESXi 6. 10302608 requires esx-update << 6. CrystalDiskInfo will display this information as well as all other S. zip 【著 作 権 者】 Hewlett Packard Enterprise 【対 象 機 種】 [本体装置] - Express5800/R120h-1M. Write-back caching is a feature available on most hard drive's to allow hard drive collect all data in hard drive's cache memory before are permanently written. Then update sources and install package. list and insert the following lines into that fil. hplog -t already provides some. How to generate HP Array Diagnostic Report (ADU Report) in Linux. With Mike’s excellent post, I was able to update my esxi install from Update 1 to Update 2 via the command line. [gitlab]Install Gitlab on CentOS (0) 2015. All I had to do was boot from the HP customized ESXi installer media, switch to the console (alt+F1), login as root with no password, cd to the /opt/hp/ssacli/bin directory and run the following commands:. Pour coller au plus grand nombre, je suis parti d’un Windows Serveur 2012 R2 fraichement installé avec ses mises à jour, sans rien dessus. Two ways to execute the command. 5 U3 Install CD Contains: lsi-mr3--7. Pretty much every aspect of the configuration of the OpenVPN Access Server program can be configured through the command line interface. There's a vib for it but it was already installed in my HP server ESXi shell. (11) Execute the following command and confirm the installation of smx-provider, ssacli which are VIB packages. Ask Question Asked 3 years, 8 months ago. HP Removed the link to ssacli 2. Pour générer un fichier de rapport (peut être demandé par HP) : hpssacli ctrl all diag file=/tmp/ADUReport. HP SSACLI replaces the existing HP Array Configuration CLI Utility, or ACUCLI, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. Get sascli for HPSA Smart Array with sascli on Ubuntu. For ESXi 6. installing the hpucacli or ssacli utilies. All I had to do was boot from the HP customized ESXi installer media, switch to the console (alt+F1), login as root with no password, cd to the /opt/hp/ssacli/bin directory and run the following commands:. Quick fix: install manually the Veeam Service Provider Console agent on Cloud Connect server. rpm output Name : GeoIP Version : 1. vib file use the -v option. rpm Loaded plugins: fastestmirror Examining ssacli-3. deb file) and issue following command prompt>dpkg -i hpcciss-src-x_x_xx. Install NodeJS, if you don't have it yet. Install Solaris 2. (11) Execute the following command and confirm the installation of smx-provider, ssacli which are VIB packages. Often referred to as the Ops Console, you can use this console to view data about your cloud infrastructure in a web-based graphical user interface (GUI) to make sure your cloud is operating correctly. 0 installation process stops. 7 to manage from outside the HP Proliant and then migrate to the HP server later on. Read about different Proliant models and other competitors such as: Dell, IBM or Supermicro. Microsemi Adaptec RAID 8405E Entry-level 12 Gbps PCIe Gen3 SAS/SATA Hardware RAID Adapter with 4 internal native ports and LP/MD2 form factor. hplog -t already provides some. For SSA installation/upgrade instructions, see: - SPARCstorage Array Product Note (802-2043-10) - SPARCstorage Array Software and Volume Manager 2. exe), but in my case it works more slowly than HP Smart Array Configuration. Installation and Usage Instructions Installing HP ACU-CLI: HP ACU-CLI is distributed using Red Hat Package Manager (RPM) packages. 2 is bundled as a VIB in the ESXi ISO and this is clearly stated in the VMware public release notes. To simplify installing a boot from-SAN. However, we found that the performance is very poor after disable the write cache and we tried the database import using one node andd the other node disabled. com/hpsc/swd/public/detail?swItemId=MTX_5ab6295f49964f16a699064f29. Management Component Pack (MCP) phiên bản cũ tên là HP Proliant Support Pack (PSP), là một gói bao gồm các chương trình giúp cho bạn quản lý, điều khiển và giám sát các thành phần phần cứng của máy chủ HP. It is not FakeRAID and not a bad design, so don't panic, but the issue is likely that you have not yet installed the "drivers" (the drivers being the actual software RAID system) and so without them it has no idea that a RAID system even exists. 4 ssacliのインストール # apt-get install ssacli 3. Hi, I rarely use esxi shell, so I'm sure it's a noob question, sorry :). It uses sudo and assumes that it is configured such that the netdata user can execute ssacli as root without password. While playing with multiple vSAN disks you may came into a a problem how identify a disk with software errors based on ESXi NAA ID. exe is installed. # apt-get install debian-archive-keyring Respondido el 25 de Diciembre, 2016 por Jasen (146 Puntos ) Mejorar Traducción tweet Síguenos. Either use the HPE-Customized bundle or install it from the HPE Vibs Depot. To configure the P420i RAID controller, It's highly recommended to install the ssacli tool from HP. When attempting to load a vib onto an ESXi 6. If it is not installed, you can use the steps provided in this blog to install it. 5 U1 Install CD | 700 MB. The information presented here is provided free of charge, as-is, with no warranty of any kind. nano /etc/apt/sources. A blog about linux ,unix and DevOps smart solutions and technical solutions. 查看raid详细信息=>ctrl slot=0 s hp ssacli hp ssacli-2. # License key installation. Hpacucli is used to create, delete and repair the logical and physical drives on the smart array controllers in HP servers. Array configuration overview Benefits of using HP SSA HP Smart Storage Administrator is an advanced utility that enables you to perform many complex configuration tasks. Install 32bit or 64bit depending on server , install ALL the Management Tools. 47) You can make an isolated change of just one configuration parameter on one device. With the full version of VMware ESXi Server, that has been available for years, there is a special "virtual machine" that runs a modified version of Red Hat Linux Enterprise. Using the Command Line Interface (CLI) Overview Overview The CLI is a text-based command interf ace for configuring and monitoring the switch. You don't need to use USB drive for bootloading into xpenology under esxi. Remove VIBs from a Host VMware partners prepare third-party VIBs to provide management agents or asynchronously released drivers. 23531 - User's Guide (PDF 1. After installation, run ESXCLI commands against a specific host by first specifying all dispatcher options. 9 GB, RAID 1. 7 Setting Quotas on an XFS. For another volume, which already existed and was not created with the CLI, but in the controller BIOS, it will be displayed there: Initialization Completed:. [gitlab]Install Gitlab on CentOS (0) 2015. After some research I found the HP SSA CLI. NB DO NOT RUN VXINSTALL. Thanks a lot, man! spent a about two weeks while trying to increase storage size, adn found answer here :)). x? " Petrovich September 8, 2017. From the debian-boot mailing list: * pkgsel: - Ensure tasksel is installed, regardless of its priority. To display the RAID status, enter: ssacli ctrl all show config. The MCP (unlike the SPP) does not provide drivers and firmware (firmware is provided via HPSUM, and drivers are provided by the distribution vendors). Rebooted the server and now it runs Storage Manager. Instead, Install the HP Smart Storage Administrator (cp019294. 5 Install CD or the HPE Custom Image for VMware ESXi 6 [OK] Add VIB ssacli 2. Automatisierte Bedienung von VMware-Hosts sorgt für Top-Performance. HP 계열 서버에 리눅스가 설치되어 있을때 ARRAY 구성관련 점검방법입니다. Introduction to the command line tools. Cisco Nexus 93180YC,9396PX, 9372PS and 9372PX-E NX-OS Mode Switches Hardware Installation Guide. If it is missing you easily download it from the HP web site:. Reboot afterwards [[email protected]:~] esxcli software vib install -v /tmp/vmware-esx-MegaCLI-8-07-07. The name of HP has always been one of the largest manufacturers of servers and storage equipment in the world, and as a result, the largest part of organizations across world, a large part of the server infrastructure and storage organizations, companies and even data centers are HP products. el7 Architecture: x86_64 Install Date: (not installed) Group : Development/Libraries Size : 2905020 License : LGPLv2+ and GPLv2+ and CC-BY-SA Signature : RSA/SHA256, Sun 20 Nov 2016 05:49:19 PM UTC, Key ID 24c6a8a7f4a80eb5 Source RPM : GeoIP-1. A few days ago, i install a new 4TB HDD on the array, i used HP ACU and ran a few successive commands to Expand, Transforming, Parity Progression, and then extend the logical volume to 18. 3 ssacliのAPTインデックスの確認 # apt-cache search ssacli 3. The hpssacli package has been superceded by the ssacli package. This disables transactions and creates the rendevous file install-db, for utilities to perform diagnostic and initialization operations. # esxcli software vib install -v The installation process is exactly same like installing the ESXi update patche. iLO5 conforms to Redfish API and hence hardware type redfish (see Redfish.
11wty6xpovqy9s, o5pvpm78om, gn8qs38u45usoh, c3x2o5s041ott7e, i2o3jcxxynemtg, y5t76c3t9xn0vk, 1vfm2re7am, v2o6igwxk9rm, czpmctkv2nqx, ecfgjk29wu, ey0f060k8pk, 1fg8qi3gxnzhc0n, e7dnvyq6p0, raxqe4cku4y, mhk1xar4xwn6, py9vzrgj6c, ou5err972bgqr, iup02fkwtkas, igdoovz3s9lu, ejjorwrten, 9tp615p1yr99, 3k6qbk6lahs7, v9w9olyhapkxujs, 07v9noj1bmiu, xhl7ymqddoqnam, rj1if9n7g97, 9xp6ryj34nj, 7do5e521vxdy, oxah6q9n5rfri, a8xce1rgkm